Prerequisite
Intaglio must be sprayed with CAD spray otherwise the intaglio will not be detected
by the scanner.
Steps
-
From the Scan List, select
Intaglio.
-
From the Camera View, set the
blue rectangle over the intaglio.
Note:
If necessary, use the mouse wheel to change the size of the
rectangle.
-
Position the blue circles over the reference circles of the reference jig.
Note:
Position the blue circles over the same set of reference circles. It
does not need to be the same set used to scan the locators.
-
Click Scan.
-
From the Scan View, rotate the scan to verify if scanning is complete. If the scan is
incomplete, refer to Adding a Scan